0 1 2

DB25 Interface

For the diagram below, we use a POS system using an RJ45-DB25 cable

for example. Depending on the POS system interface, find out the DB25 Female or DB25 Male connector on the GV-Data Capture for connection.

► POS system using an RJ45-DB25 cable

System Configuration

You must configure the GV-System before it will be overlaying transaction data on video footage.

1. Run the GV-System.


П) rj-45

POS System

DB25 Female / Male У



DB25 Male / Female

A DB9 Female DB9 Male -

DB25

Э rs-232

Female / Male 3 rs-232

Printer

2. Click the Configure button, point to POS Application Setting, and select POS Device Setup. This displays the POS Server Setup dialog box.

3. Click the New button to display the COM setting dialog box as shown below.


• The RJ-45 cable fi> is supplied with the POS system.

• The RS-232 cables и Й are supplied with the GV-Data Capture box.

• The physical distance between the POS system and GV-System should be less than 10 meters (32 ft).

► Printer Type: Select Serial Port for this application.

► Device: Assign the POS system to a camera channel. POS 1 displays images and data on the Camera 1 channel; POS 2 on the Camera 2 channel, and so on. Click the button [...] next to the item to rename the device.

► POS Module: Select the printer connected to the POS system. If its not Epson, select General for other brands.

► COM Port: Select the COM port connected to the POS system.



► The parameter button: Click this button to configure the following parameters or keep default settings.

Baud Rate: Select the baud rate corresponding to that of the POS system. Data Bits: Select the data bit corresponding to that of the printer. Parity: Select None for the serial POS system. Stop Bits: Select the stop bit corresponding to that of the printer.

► Cash Drawer Open Signal: This option is only available when an input module is configured in the main system. Assign the input module connected to the cash drawer. Every time when the cash drawer is open, it will be recorded in System Log for later retrieval.

► Trace Mode: Check this option only after getting the recommendation from our technical support staff.

4. After above settings, click Add to add the POS system to the GV-System.

Cash Register Connection

In this manual, cash registers refer to those with receipt printers internally connected. Cash registers may not be integrated to GV-Systems, unless with the following characteristics. Please check these characteristics before actually connecting your cash register to the GV-System.

Check if your cash register has an output port for a printer.

Connect a receipt printer to the output port and see if it functions well.

If it does, the integration is then possible.

Note: If display errors happen when connecting the receipt printer to the cash register (e.g. drop caps, character display errors), the same problems would remain when the GV-System overlays data on video footage.

As POS systems, cash registers also have two types of interfaces: DB9 and DB25. Following will introduce the two interface connections.

DB9 Interface

Depending on the cash register interface, find out the DB9 Female or DB9 Male connector on the GV-Data Capture for connection.

DB9 ф RS-232 Female / Male

DB9 Male / Female


Cash Register


GV-System

DB9 Female

DB9 Male

[2> RS-232

The RS-232 cables <1 <2 are supplied with the GV-Data Capture box. The physical distance between the POS system and GV-System should be less than 10 meters (32 ft).



DB25 Interface

Depending on the cash register interface, find out the DB25 Female or DB25 Male connector on the GV-Data Capture for connection.


DB25

ni RS-232

Female / Male "

DB25 Male / Female

Cash Register


GV-System

DB9 Female

DB9 Male

13 RS-232

The RS-232 cables (1 (2 are supplied with the GV-Data Capture box. The physical distance between the POS system and GV-System should be less than 10 meters (32 ft).

System Configuration

You must configure the GV-System before it will be overlaying transaction data on video footage. Follow the same settings as previously described in the POS System Connection section.

Extending Distance

The previous diagrams assume that the physical distance between the POS system and GV-System is within 10 meters (32 ft). If the distance between the two devices is greater than 10 meters, it is required to use (1) GV-NET series or (2) GV-Hub in the connection.

► Using GV-NET series in the connection


RS232

POS system

RS485 J GV-NET box or GV-NET card or GV-Data Capture GV-NET I/O card


GV-System

► Using GV-Hub in the connection


RS232 i м& i RS485


POS system

GV-Data Capture GV-Hub

GV-System

Note: The maximum distance of RS-485 is 1200 meters (4000 ft)